ISO 12944 |
 PART 1 |
|
 PART 3 & 4 |
|
 |
SISTEM ISO 12944 Ti.Pi.Ci. |
ISO 12944-2 - Environment classification
ISO 12944-2 is about main environment classification where steel structures are exposed to relevant corrosivity. ISO 12944-2 is not about those environment classification with peculiar atmosphere (for example chemical plants or metallurgical’s or around their proximities).
| class |
Atmospheric environment corrosivity definition:
|
|
class |
For submerged or buried structures:
|
| C1 |
Very low |
|
Im1 |
Fresh Water |
| C2 |
Low |
|
Im2 |
Salt or Brackish Water (without cathodic protection)
|
| C3 |
Medium
|
|
Im3 |
Soil
|
| C4 |
High
|
|
Im4 |
Salt or Brackish Water (with cathodic protection)
|
| C5 |
Very High |
|
|
|
| CX |
Extreme
|
|
|
|
PLEASE NOTE: about most of cases regarding dipping or burial it must be considered it could be applied a cathodic protection to the structures
ISO 12944-2 IS NOT ABOUT protective functions for particular strains
| PARTICULAR SITUATIONS |
|
PARTICULAR STRAINS |
| Internal building corrosion |
|
Chemical stress |
| Corrosion into boxed components |
|
Mechanical stress |
| |
|
Medium temperature stress (from +60 to +150°C) |
| |
|
High temperature stress (from +150 to +400°C) |
| |
|
Condensation stress (continue or long duration) |
| |
|
Combined stress |
|